摘要: 岩石变形导致的温度变化极其微弱,对观测系统与环境有严格要求。正确选择红外观测系统的参数,配备高灵敏度的温度场观测设备,以及有效地控制环境热背景决定了变形热红外实验结果的可靠性。在对噪声与干扰源进行详细分析的基础上,提出了进行热红外实验所需要的各主要设备的关键技术指标,并建立了一套相应的实验系统。典型材料样品实验表明,在考虑到变形热红外实验的各种特殊要求,认真选择观测设备,并进行了严格的误差校正之后,可以获得可靠的变形热过程信息。

关键词: 热红外, 观测系统, 岩石变形实验

Abstract: The infrared signals produced during rock deformation are very faint and tiny,so that the measurements of them require excellent capabilities of detection system and strict working environment. The reliability of the results of infrared experiment,therefore,depends greatly on the reasonable technical specifications of infrared photodetector,high sensitivity recorder for temperature field and effectively controlled thermal background. All of the key parameters are discussed in detail in this paper based on laboratory infrared observation. The features for an infrared camera include spectral band,digitizing resolution,view field etc. For capturing the optimal infrared images,it is suggested that the spectral range should be 7~13μm,the observation range should be from 0.5m to infinity,and high-density focal plane array should be employed as far as possible. In order to confirm the temperature from infrared image,a surface temperature recorder with multi thermometers should be employed as an eyewitness working alongside the camera. A realistic experiment system has been developed based on the afore mentioned discussion. Aside from the traditional functions of infrared camera,the system is fitted with high-speed data transmission component. The infrared focal plane array has 320×240 pixels,and 25 frames of temperature field data are saved into the hard disk per second. Some steel beam bending and steel cylinder compressing experiments were made for testing the system. The tests have proved that the system is reliable and the data quality is improved greatly.

Key words: infrared, detection system, rock deformation experiment